Page tree


Status In progress
Version0.1
Version in PROD



1.1. Descriptions:

Term

description type

Language/acceptability

Language/acceptability

Case significance

Fluoroscopic angiography of [body structure] with [substance] and insertion of stent (procedure)

FSNus:Pgb:Pci
Fluoroscopic angiography of [body structure] with [substance] and insertion of stentPTus:Pgb:Pci


  

1.2. Concept model:

1.3. Definition status:  


900000000000073002 |Sufficiently defined by necessary conditions definition status (core metadata concept)|

1.4. Applies to:

<< 103716009 |Placement of stent (procedure)|: 260686004 |Method| = << 312275004 |Fluoroscopic imaging - action (qualifier value)|, [0..0] 363703001 |Has intent (attribute)| = 429892002 |Guidance intent (qualifier value)|

1.5. Template language:


71388002 |Procedure (procedure)|    : 
[[~1..* @AngioRoleGroup]]{ 
[[~1..1]]   
260686004 |Method (attribute)|    = [[ +id (    312275004 |Fluoroscopic imaging - action (qualifier value)|    ) @Imagingaction ]] , 
[[~1..1]]   
405813007 |Procedure site - Direct (attribute)|    = [[ +id ( <<    59820001 |Blood vessel structure (body structure)|    ) @Bloodvessel ]] , 
[[~1..1]]   
424361007 |Using substance (attribute)|    = [[ +id ( <<    385420005 |Contrast media (substance)|    ) @Substance ]] , 
[[~0..1]]   
363700003 |Direct morphology (attribute)|    = [[ +id ( <    49755003 |Morphologically abnormal structure (morphologic abnormality)|    ) @Morphology ]] } 

[[~1..* @StentRoleGroup]]{ 
[[~1..1]]   
260686004 |Method (attribute)|    = [[ +id (   257867005 |Insertion - action (qualifier value)|    ) @Insertionaction ]] , 
[[~1..1]]   
405814001 |Procedure site - Indirect (attribute)|    = [[ +id ( <<    59820001 |Blood vessel structure (body structure)|    ) @Bloodvessel ]] , 
[[~1..1]]   
363699004 |Direct device (attribute)|   =   [[ +id ( <<  65818007 |Stent (physical object)|    ) @Stentdevice ]]}


1.6. Link to the misaligned concept report:

https://docs.google.com/spreadsheets/d/1F5YMfKuy6DmcqdhUGafvZ9PgN9nXxiaBITfSVMuRyKg/edit#gid=1

1.7. Rules for generating descriptions:

  1. Apply General rules for generating descriptions for templates;
  2. Apply Enhancements for the Template Language;
  3. If the direct site of the angiography (@AngioRoleGroup) is specified as an artery rather than a blood vessel, an additional description should be added SYN: Fluoroscopic arteriography of [body structure] with [substance] and insertion of stent, should be added as acceptable in both US/GB and case significance should be ci. 
  4. If the direct site of the angiography (@AngioRoleGroup) is specified as an vein rather than a blood vessel, an additional description should be added SYN: Fluoroscopic venography of [body structure] with [substance], should be added as acceptable in both US/GB and case significance should be ci. 
  • No labels