Patrick McCormick Steven Dain Grant Forrest Andrew Marchant Monica Harry Saswika Baidjoe Cato Christian Spook Jeremy Rogers
There are 8 subtypes of 241692007 |Inhalational induction (procedure)|. Six of these subtypes are complex concepts primarily created in 2002 with last modification in 2022.
All theses concepts are leaf nodes and there are no specific references in literature (at least from my perspective).
- 24277005 |Inhalation anesthesia, machine system, closed, circulation of primary agent (procedure)|
- 44812007 |Inhalation anesthesia, machine system, closed, no rebreathing of primary agent (procedure)|
- 112987001 |Inhalation anesthesia, machine system, closed, rebreathing of primary agent (procedure)|
- 64287005 |Inhalation anesthesia, machine system, semi-closed, circulation of primary agent and gases (procedure)|
- 30050007 |Inhalation anesthesia, machine system, semi-closed, no rebreathing of primary agent (procedure)|
- 27653002 |Inhalation anesthesia, machine system, semi-closed, rebreathing of primary agent (procedure)|
Q1: Are these concepts up-to-date?
Q2: Are these concepts useful for clinical register?
Q3: If useful:
- Should be kept under 241692007 |Inhalational induction (procedure)|?
- Should be moved to be subsumed by 288185006 |Inhalation general anesthesia (procedure)|?
4 Comments
Victor Medina
Hi everyone. Is there any comment about this issue? Thanks.
Steven Dain
Q1. I think they are up to date
Q2. They are useful for documentation on an anesthetic record
Q3. Should be moved to be subsumed by 288185006 |Inhalation general anesthesia (procedure)|
Cato Christian Spook
I agree with Steven Dain on Q1, Q2 and Q3.
Patrick McCormick
Possibly useful reference discussion here on closed vs semi-closed and rebreathing:
https://www.openanesthesia.org/keywords/anesthesia-breathing-systems/