Page tree

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 28 Next »

Content Tracker

Release Date

20240401

Release Status

PRODUCTION

Document Version

1.0


© 2024 International Health Terminology Standards Development Organisation.  All rights reserved.  SNOMED CT® was originally created by the College of American Pathologists.

This document forms part of the International Edition release of SNOMED CT® distributed by International Health Terminology Standards Development Organisation, trading as SNOMED International, and is subject to the SNOMED CT® Affiliate License, details of which may be found at  https://www.snomed.org/snomed-ct/get-snomed.

No part of this document may be reproduced or transmitted in any form or by any means, or stored in any kind of retrieval system, except by an Affiliate of SNOMED International in accordance with the SNOMED CT® Affiliate License. Any modification of this document (including without limitation the removal or modification of this notice) is prohibited without the express written permission of SNOMED International.

Any copy of this document that is not obtained directly from SNOMED International [or a Member of SNOMED International] is not controlled by SNOMED International, and may have been modified and may be out of date. Any recipient of this document who has received it by other means is encouraged to obtain a copy directly from SNOMED International [or a Member of SNOMED International. Details of the Members of SNOMED International may be found at http://www.snomed.org/members/].



Page At A Glance

Table Of Contents



Introduction

Background

SNOMED CT terminology provides a common language that enables a consistent way of indexing, storing, retrieving, and aggregating clinical data across specialties and sites of care.

SNOMED International maintains the SNOMED CT technical design, the content architecture, the SNOMED CT content (includes the concepts table, the descriptions table, the relationships table, a history table, and ICD mappings), and related technical documentation.

Purpose

This document provides a summarized description of the content changes included in the April 2024 release of SNOMED Clinical Terms® (SCT) International Edition.

It also includes notes detailing the known content or technical issues where the root cause is understood, the fix has been discussed and agreed to, but has yet to be implemented.

The SNOMED International release notes are available alongside the April 2024 International Edition.

Scope

This document is written for the purpose described above and is not intended to provide details of the technical specifications for SNOMED CT or encompass every change made.

Audience

The audience includes National Release Centers, WHO-FIC release centers, vendors of electronic health records, terminology developers and managers who wish to have an understanding of changes that have been incorporated into the April 2024 International Edition.

Please note, you may have to register for a Confluence user account in order to access the links included in these release notes.

Important Information

NOTICE

UPCOMING CHANGES TO THE ANNOTATIONS REFSET FORMAT

After discussions with the community, SNOMED International has agreed to make changes to the coverage of language in the Annotations refsets in the following way:

  • The langueCode field was specified as the two characters of ISO-639-1 code for the language of the annotation text. The change is to include support for specifying dialect when it is applicable by adhering to RFC 5646, which allows the combination of two characters of ISO 639-1 code and two uppercase letters of country code (ISO 3166) separated by a hyphen. 
  • The "languageCode" changed to "languageDialectCode" in the field column.
  • 1296895003|Language code (foundation metadata concept)| inactivated and replaced by 1304275002 |Language or dialect code (foundation metadata concept)|
  • The changes apply to both the Member Annotations String Value Reference Set + Component Annotation String Value reference set

These changes will be implemented in one of the 2024 monthly International Edition releases, once the development work has been completed and tested.  We will notify the community which release contains the changes once this has been confirmed.

Content Development Activity

Summary

Continuous quality improvement and enhancement of existing content is an ongoing process undertaken by SNOMED International in preparation for every release. The April 2024 International Edition has seen a continuation of the work driven by contributions from: Kaiser Permanente i.e. Convergent Medical Terminology (CMT), Global Medical Device Nomenclature Agency (GMDNA), Orphanet and other domain specific collaborations as well as requests received via the Content Request System (CRS). 

Additionally quality improvement activities are advanced via project driven initiatives summarized below.  Additional work items impacting every release are updates to the SNOMED CT derived maps such as ICD-10 and ICD-O; details are included in these release notes.  

Information about editorial decisions may be found in the SNOMED CT Editorial Guide; mapping guidance for ICD-10 can be found here.

Quality Initiative

The Quality Initiative (QI) project is the implementation of the Quality Strategy. After a successful pilot project for the July 2018 Edition release, the next stage has been implemented for subsequent releases including April 2024. 

Quality improvement tasks are being deployed to improve internal structural consistency and ensure compliance with editorial policy related to the stated modeling of content. Additionally, correction or addition of defining relationships is being carried out to accurately reflect current clinical knowledge and ensure the semantic reliability of descriptions associated with a concept.  

Update 205237003|Pneumonitis (disorder)| and 233604007|Pneumonia (disorder)|

Concepts in the hierarchy 205237003|Pneumonitis (disorder)| and 233604007|Pneumonia (disorder)| have been reviewed and remodeled to reflect current knowledge.

Pneumonitis does not necessarily have an infectious cause and so the content has been remodeled to reflect this. The body site has been updated to 113255004 |Structure of parenchyma of lung (body structure) and the morphologic abnormality has been updated to 409774005 |Inflammatory morphology (morphologic abnormality) or a descendant. Pneumonia concepts are subtype of pneumonitis with an infectious cause and the content in this area has been modeled to align accordingly.

Number of concepts edited (approx): 270

Update 35631009 |Laser surgery (procedure)|

424244007 |Using energy (attribute)| with range << 38586004 |Laser-generated electromagnetic radiation (physical force)|  has been added for laser surgery procedures. Work for the area of 35631009 |Laser surgery (procedure)| remains ongoing.

Number of concepts edited (approx): 46

Update 133864008|Lithotripsy (procedure)|

The method for 133864008|Lithotripsy (procedure)| and subtypes has been updated from 129400007 |Crushing - action (qualifier value)| to 129401006 |Fragmentation - action (qualifier value)|.

In addition to this 424226004 |Using device (attribute)| and 424244007 |Using energy (attribute)| have been added as required.

Number of concepts edited (approx): 79

Update 27411008|Cauterization (procedure)|

The definitional status for 27411008 |Cauterization (procedure)| has been updated to sufficiently defined.  43802008 |Thermocauterization (procedure)| has been remodeled to eliminate Using device (attribute)|.

 Body Structure 

 Inactivation of 9258009|Gravid uterus structure (body structure)|

9258009|Gravid uterus structure (body structure)| has been inactivated, content that is modeled with this concept has been remodeled with a site of 35039007|Uterine structure (body structure)| along with occurrence <<307159006|Pregnancy time period (qualifier value)|.

The domain of 246454002 |Occurrence (attribute)| was extended in the October 2023 release to include << 71388002 |Procedure (procedure)| to support these content changes. Content areas that have been updated include 386811000|Fetal procedure (procedure)| and 386637004|Obstetric procedure (procedure)|.

Inactivation of Breast Structure Concepts that Specify Male/Female

Following consultation with the community of practice, 67770001 |Male mammary gland structure (body structure) and 91532001 |Female mammary gland structure (body structure) and subtypes plus their associated disorder and specimen concepts have been inactivated. Further information is available here.

This update includes the inactivation of neoplasm concepts that specify male/female:

<<126927001|Neoplasm of female breast (disorder)|

<<126937006|Neoplasm of male breast (disorder)|

The inactivation reason is ‘Non conformance to editorial policy’ and the inactive concepts have been replaced with a concept that does not specify male/female where one does not already exist.

SEP and Laterality Anatomy Reference Sets

The release file for the lateralizable body structure reference set has been updated and validated.

The release file for the SEP reference set has been updated and validated.

Procedure

Radiographic Imaging/Plain X-Ray

The first phase of work for this Content Tracker has been published in the April 2024 International Edition. 

These changes follow wide consultation with the community of practice, more information about this is available here and also see blog here.

Work has been undertaken in the following areas:

  • 168537006|Plain radiography (procedure)| and subtypes
  • 168500000|Radiology result normal (finding)| and subtypes
  • 168501001|Radiology result abnormal (finding)| and subtypes

Content in the ‘situation with explicit context’ and also ‘clinical finding’ hierarchies has been updated where it has been impacted by the changes to the procedure content. New editorial guidance has been drafted and will be published to accompany the content changes. A new template has been created for ‘Plain X-ray of..’ and is currently in review.

This first phase excludes X-ray guided procedures, X-ray tomography, digital tomosynthesis, mammography.  Content changes for <<363680008|Radiographic imaging Procedure (procedure)| will continue for this project throughout 2024 until complete.  

Review 118661008|Physician service (procedure)| and Subtypes

118661008|Physician service (procedure)| and subtypes have been inactivated and replaced with concepts that are a subtype of 224891009|Healthcare services (qualifier value)| where appropriate. Concepts that were not inactivated such as

117615005|Report of transfusion reaction (procedure)| have been remodeled to remove the IS_A relationship to 118661008|Physician service (procedure)|

These changes were implemented to complete this Content Tracker.

Physical Object

Brachytherapy Devices

As part of the review for the 1287742003 |Radiotherapy (procedure)| hierarchy, updates have been made for the devices used in brachytherapy in order to improve subsumption.

Number of concepts edited (approx): 55

Qualifier Value

Update 410460000|Illumination - action (qualifier value)|

410460000|Illumination - action (qualifier value)| and descendants have been updated to be a subtype of 272394005|Technique (qualifier value)|. Descriptions that currently include “- action’ have been been inactivated and replaced.

Procedure concepts that are currently modeled with method 410460000|Illumination - action (qualifier value)| have been remodeled with a method of 360037004|Imaging - action (qualifier value)|.

These changes complete this Content Tracker.

Collaboration/Harmonization Agreements

Convergent Medical Terminology (CMT)

55 new concepts plus supporting concepts as required (anatomy, non lateralised parents) have bee added with focus on injuries and endometriosis.

Orphanet

Working in collaboration with Orphanet (http://www.orpha.net/consor/cgi-bin/index.php), efforts are ongoing to update rare disease concepts in SNOMED CT to maintain alignment with Orphanet for the annual update of the SNOMED CT to Orphanet Maps.

All of the concepts added for the Orphanet project have been mapped to ICD-10.

Cancer Synoptic Reporting

Cancer synoptic reports are used by many member countries to record pathology examination of cancer specimens including the College of American Pathologists (US and Canada), Royal College of Pathology (UK), Royal College of Pathology Australasia (Australia, New Zealand), PALGA (The Netherlands), Swedish Society of Pathology, and others.

For more information about this project, please see Cancer Synoptic Reporting Clinical Project Group 

International League Against Epilepsy (ILAE)

In line with approved harmonized terminology, this project is working on alignment including restructuring to update the hierarchy  << 313307000 |Epileptic seizure (finding)|.

Further information about the project is available here

Gravity Project

Work is ongoing for this project. 

Internal Quality Improvement

Machine Readable Concept Model (MRCM) Changes

No  changes have been made for the April 2024 release.

Future changes that are currently in progress can be viewed via the MRCM Daily Build Browser

Please see early visibility for future planned changes to MRCM.

OWL Axiom Expressions for Annotation Properties

The new annotation properties are represented in the OWL expression axiom refset as follows:

  • The 1295447006 |Annotation attribute (attribute)| is correctly represented as subClassOf

    • 01300ccd-d1d7-417d-a70a-f688e72c4d8c 20231201 1 900000000000012004 733073007 1295447006 SubClassOf(:1295447006 :246061005)

  • All subconcepts of 1295447006 |Annotation attribute (attribute)| are represented as "SubAnnotationPropertyOf", instead of "subClassOf" as they previously were

    • e6cd65fe-cb81-4db4-9ac4-040dc74fce28 20231201 1 900000000000012004 733073007 1295448001 SubClassOf(:1295448001 :1295447006)

    • 3729ce47-a96e-4dc7-9eff-83c34740c414 20231201 1 900000000000012004 733073007 1295449009 SubClassOf(:1295449009 :1295447006)

These axiom updates are published in the March 2024 International Edition release. The authoring tool has been updated to ensure all new subconcepts of 1295447006 |Annotation attribute (attribute)| are represented as SubAnnotationPropertyOf(). Other tools will be updated to correctly consume the updated syntax. This will be carefully tested and rolled out over the next few months.

SNOMED CT derived products

ICD-10 map

The SNOMED CT to the International Statistical Classification of Diseases and Related Health Problems, Tenth Revision (© World Health Organization 1994) 2016 Version map (SNOMED CT to ICD-10 Map) is included in the SNOMED CT International Edition as a Baseline. The SNOMED CT to ICD-10 Map was created to support the epidemiological, statistical and administrative reporting needs of SNOMED International member countries and WHO Collaborating Centers.

The SNOMED CT to ICD-10 Map is released in Release Format 2 (RF2) only. It is located in the file der2_iisssccRefset_ExtendedMapFull_INT_20200731.txt, which is in the Map folder under Refset, in each of the three RF2 Release Type folders. 

The SNOMED CT to ICD-10 Map is released as Refset 447562003 |SNOMED CT to ICD-10 extended map (foundation metadata concept).

The ICD-10 Mapping Technical Guide (including exemplars) is hosted here https://confluence.ihtsdotools.org/display/DOCICD10

Content Development Activity Summary

The map is a directed set of relationships from SNOMED CT source concepts to ICD-10 target classification codes.  The SNOMED CT source domains for the MAP are limited to subtypes of 404684003 |clinical finding|, 272379006 |event| and 243796009 |situation with explicit context|.  The target classification codes are ICD-10 2016 release. 

Mapped content for April 2024

The map provided for the April 2024 International Edition has been updated, and now represents a complete map from SNOMED CT International Edition to ICD-10 2016 version.

  • 365 newly authored concepts have been added and mapped.

  • The SNOMED to ICD-O (morphology) map has 2 additional concepts added as a result of the ICD-O 3.2 review or added due to CRS requests. 

We would welcome feedback on any issues that users of the map may detect when using the map. Issues should be submitted via mapping@snomed.org

SNOMED CT to OWL conversion and classification

The repository containing the toolkit enabling simple SNOMED CT to OWL conversion and classification can be found here, including documentation on its use: https://github.com/IHTSDO/snomed-owl-toolkit

Please contact SNOMED International at support@snomed.org if you would like to provide any feedback on ways to extend and improve the new toolkit.


Technical notes

Known Issues

Known Issues are content or technical issues where the root cause is understood, and the resolution has been discussed and agreed but has yet to be implemented.  This can be due to a number of reasons, from lack of time within the new monthly editing cycles, to the risk of impact to the stability of SNOMED CT if the fix were to be deployed at that stage in the Product lifecycle.  

For the current SNOMED CT International edition, the following Known Issues were identified, and agreed to be resolved in future editing cycles:


Key Summary Description
Loading...
Refresh



Resolved Issues

Resolved issues are Known Issues which were not fixed as part of the previous release lifecycle, but which have now been resolved in the latest release.  They can also be issues found during testing of the current release, which were resolved before the final deployment of the Production release.  Finally they can be issues which were reported or found during the testing phase, but which have been closed without any action taken.  

The Resolved Issues for the current SNOMED CT International edition can be found here:

Key Summary Description Resolved
Loading...
Refresh

Technical updates

RF2 package format

The RF2 package convention dictates that all relevant files are included, regardless of whether or not there is content to be included in each release.  Therefore, the package contains a mixture of files which contain both header rows and content data, and files that (intentionally) include only header records.  The reason that these "empty" files are included in the package is to draw a clear distinction between:

  1. ...files that have been deprecated (and therefore removed from the package completely), due to the content no longer being relevant to RF2 in future releases 

  2. ...files that happen to contain no data in this particular release (and are therefore included in the package with just a header record), but are still relevant to RF2, and could therefore contain content in future releases.

This allows users to easily distinguish between the two scenarios, as otherwise if files in option 2 were left out of the package it could be interpreted as an error, rather than an intentional lack of content in that release.

Changes to the International Edition package format

In line with the new implementation of Annotations, two new refsets have been added to the International Edition Release package, from December 2023 onwards:

  • der2_scsRefset_ComponentAnnotationStringValueSnapshot_INT_20240101.txt
  • der2_sscsRefset_MemberAnnotationStringValueSnapshot_INT_20240101.txt

These refset files are empty for the April 2024 release, whilst content is authored in future editing cycles.  However, they will then be populated with Annotations data from one of the future 2024 International Edition releases onwards (date to be confirmed).  These improvements were introduced in the December 2023 International Edition release, and will be used in all future International Edition releases until further notice.

If you have any feedback on the format of these new files please provide it URGENTLY, as changes can potentially be made now (subject to relevant approvals), before the files are populated. 

Proposed change to the Annotations Refset format


NOTICE

UPCOMING CHANGES TO THE ANNOTATIONS REFSET FORMAT

After discussions with the community, SNOMED International has agreed to make changes to the coverage of language in the Annotations refsets in the following way:

  • The langueCode field was specified as the two characters of ISO-639-1 code for the language of the annotation text. The change is to include support for specifying dialect when it is applicable by adhering to RFC 5646, which allows the combination of two characters of ISO 639-1 code and two uppercase letters of country code (ISO 3166) separated by a hyphen. 
  • The "languageCode" to be changed to "languageDialectCode" in the field column.
  • 1296895003|Language code (foundation metadata concept)| to be inactivated and replaced by 1304275002 |Language or dialect code (foundation metadata concept)|
  • The changes will apply to both the Member Annotations String Value Reference Set + Component Annotation String Value reference set

These changes will be implemented in one of the 2024 monthly International Edition releases, once the development work has been completed and tested.  We will notify the community which release contains the changes once this has been confirmed.

Early visibility of impending changes in the upcoming 2024 Monthly International Edition releases

Please see the early visibility Confluence page for details of forthcoming changes.

All links provide information that is correct and current at the time of this Release.  Updated versions may be available at a later date, but if so these will need to be requested from the relevant SNOMED International teams.

NOTE:  To access any of the links in the pdf document, please visit the Release Notes @ https://confluence.ihtsdotools.org/display/RMT/SNOMED+CT+April+2024+International+Edition+-+SNOMED+International+Release+notes



Approvals

Final Version

Date

Approver

Comments

1.0


Rory DavidsonApproved
1.0


Monica HarryApproved
1.0


Kelly KuruApproved


Draft Amendment History

Version

Date

Editor

Comments

0.1

 

Andrew Atkinson

First draft for review and comment

0.1


Maria Braithwaite

Donna Morgan

Content Update

Mapping Update

1.0


Andrew Atkinson 

Final Production changes

  • No labels