Descriptions:
Term | description type | Language/acceptability | Language/acceptability | Case significance |
---|---|---|---|---|
[Cemented/uncemented] [total/hybrid/partial] prosthetic arthroplasty of [joint] (procedure) | FSN | us:P | gb:P | ci |
[Cemented/uncemented] [total/hybrid/partial] prosthetic arthroplasty of [joint] | PT | us:P | gb:P | ci |
example:
Concept model:
Attribute Group Cardinality | Attribute Cardinality | Attribute in Group Cardinality | Attribute | Value |
---|---|---|---|---|
0..0 | 1..1 | |||
1..2 | 1..1 | |||
1..1 | ||||
1..* | 1..1 | |||
1..1 | ||||
0..1 | ||||
1..1 | ||||
0..1 | 0..1 | |||
0..1 | ||||
0..1 | ||||
0..1 |
Definition status:
900000000000073002 |Defined (core metadata concept)|
Applies to:
<<
1288025000 |Prosthetic arthroplasty of joint (procedure)|
Template language:
71388002 |Procedure (procedure)|
:
[[~1..2]]{
[[~1..1]] 260686004 |Method (attribute)| = [[+id( 257903006 |Repair - action (qualifier value)| )]],
[[~1..1]] 405813007 |Procedure site - Direct (attribute)| = [[+id(<< 39352004 |Joint structure (body structure)| )]]}
[[~1..*]]{
[[~1..1]] 260686004 |Method (attribute)| = [[+id(<< 129338005 |Surgical implantation - action (qualifier value)| )]],
[[~1..1]] 405814001 |Procedure site - Indirect (attribute)| = [[+id(<< 39352004 |Joint structure (body structure)| )]],
[[~0..1]] 424361007 |Using substance (attribute)| = [[+id( 6043006 |Bone cement (substance)| )]],
[[~1..1]] 363699004 |Direct device (attribute)| = [[+id(<< 15447007 |Joint prosthesis, device (physical object)| )]]}
[[~0..1]]{
[[~0..1]] 260686004 |Method (attribute)| = [[+id(<< 129284003 |Surgical action (qualifier value)| )]],
[[~0..1]] 405814001 |Procedure site - Indirect (attribute)| = [[+id(<< 39352004 |Joint structure (body structure)| )]],
[[~0..1]] 246513007 |Revision status (attribute)| = [[+id( 255231005 |Revision - value (qualifier value)| )]],
[[~0..1]] 363699004 |Direct device (attribute)| = [[+id(<< 15447007 |Joint prosthesis, device (physical object)| )]]}
[[~1..2]]{
[[~1..1]] 260686004 |Method (attribute)| = [[+id( 257903006 |Repair - action (qualifier value)| )]],
[[~1..1]] 405813007 |Procedure site - Direct (attribute)| = [[+id(<< 39352004 |Joint structure (body structure)| )]]}
[[~1..*]]{
[[~1..1]] 260686004 |Method (attribute)| = [[+id(<< 129338005 |Surgical implantation - action (qualifier value)| )]],
[[~1..1]] 405814001 |Procedure site - Indirect (attribute)| = [[+id(<< 39352004 |Joint structure (body structure)| )]],
[[~0..1]] 424361007 |Using substance (attribute)| = [[+id( 6043006 |Bone cement (substance)| )]],
[[~1..1]] 363699004 |Direct device (attribute)| = [[+id(<< 15447007 |Joint prosthesis, device (physical object)| )]]}
[[~0..1]]{
[[~0..1]] 260686004 |Method (attribute)| = [[+id(<< 129284003 |Surgical action (qualifier value)| )]],
[[~0..1]] 405814001 |Procedure site - Indirect (attribute)| = [[+id(<< 39352004 |Joint structure (body structure)| )]],
[[~0..1]] 246513007 |Revision status (attribute)| = [[+id( 255231005 |Revision - value (qualifier value)| )]],
[[~0..1]] 363699004 |Direct device (attribute)| = [[+id(<< 15447007 |Joint prosthesis, device (physical object)| )]]}
Link to the misaligned concept report:
https://docs.google.com/spreadsheets/d/13cp1b-5SNWsPDy_i9e7LuMFOcJJZwrTA-Mb34xhzP0k/edit#gid=0
Rules for description generation:
- Apply General rules for generating descriptions for templates;
- Apply Enhancements for the Template Language;