Page tree

Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.


Page properties


StatusIn progress
Version

0.1


Descriptions:

Termdescription typeLanguage/acceptabilityLanguage/acceptabilityCase significance

[Access] [Approach] insertion of stent into [body structure] using [imaging] guidance with [contrast] (procedure)

FSNus:Pgb:Pci
[Access] [Approach] insertion of stent into [body structure] using [imaging] guidance with [contrast]PTus:Pgb:Pci

example: 397057006 |Insertion of stent in femoral vein (procedure)|


Concept model:

Attribute Group CardinalityAttribute cardinality

Attribute in Group Cardinality

AttributeValue
0..01..10..0


Scg expression
116680003|Is a (attribute)|



Scg expression
71388002|Procedure (procedure)|


0..1
1..1


Scg expression
260686004|Method (attribute)|



Scg expression
[imaging] <<  360037004 |Imaging - action (qualifier value)|  



0..1


Scg expression
405813007 |Procedure site - Direct (attribute)|



Scg expression
<  442083009 |Anatomical or acquired body structure (body structure)|



1..1


Scg expression
363703001 |Has intent (attribute)|



Scg expression
429892002 |Guidance intent (qualifier value)|



0..1


Scg expression
424361007 |Using substance (attribute)|



Scg expression
[contrast] << 385420005 |Contrast media (substance)|


1..1
1..1


Scg expression
260686004|Method (attribute)|



Scg expression
<<257867005 |Insertion - action (qualifier value)|



0..1


Scg expression
405814001 |Procedure site - Indirect (attribute)|



Scg expression
[body structure] << 442083009 |Anatomical or acquired body structure (body structure)|



1..1


Scg expression
363699004 |Direct device (attribute)|



Scg expression
<< 65818007 |Stent (physical object)|



0..1


Scg expression
260507000 |Access (attribute)|



Scg expression
103388001 |Percutaneous approach - access (qualifier value)|



0..1



Scg expression
424876005 |Surgical approach (attribute)|



Scg expression
<103379005 |Procedural approach (qualifier value)|


Definition status:  


Scg expression
900000000000073002|Defined (core metadata concept)|


Applies to:

Scg expression
<< 103716009 |Placement of stent (procedure)|


Template language:


Scg expression
71388002 |Procedure (procedure)| : 
[[~0..1]]{
[[~1..1]] 260686004 |Method (attribute)| = [[+id(<< 360037004 |Imaging - action (qualifier value)| ) @imaging]],
[[~0..1]] 405813007 |Procedure site - Direct (attribute)| = [[+id(<< 442083009 |Anatomical or acquired body structure (body structure)| ) @bodyStructure]],
[[~1..1]] 363703001 |Has intent (attribute)| = 429892002 |Guidance intent (qualifier value)| ,
[[~0..1]] 424361007 |Using substance (attribute)| = [[+id(<< 385420005 |Contrast media (substance)| ) @contrast]]
}, 
[[~1..1]]{ 
[[~1..1]] 260686004 |Method (attribute)| = 257867005 |Insertion - action (qualifier value)| , [[~0..1]] 260507000 |Access (attribute)| = [[+id (<< 103388001 |Percutaneous approach - access (qualifier value)| ) @access]] , 
[[~0..1]] 405814001 |Procedure site - Indirect (attribute)| = [[+id (<< 442083009 |Anatomical or acquired body structure (body structure)| ) @bodyStructure]], 
[[~0..1]] 363699004 |Direct device (attribute)| = [[+id (<< 65818007 |Stent (physical object)| )]]}


Link to the misaligned concept report:


Rules for description generation: 

  1. Apply General rules for generating descriptions for templates;
  2. Apply Enhancements for the Template Language;

JIRA ticket: