Status | Archived |
Version | 0.2 |
Version in PROD |
Descriptions:
Term | description type | Language/acceptability | Language/acceptability | Case significance |
---|---|---|---|---|
[Imaging] angiography of [body structure] with [substance] (procedure) | FSN | us:P | gb:P | ci |
[Imaging] angiography of [body structure] with [substance] | PT | us:P | gb:P | ci |
Concept model:
Attribute Group Cardinality | Attribute Cardinality | Attribute cardinality in role group | Attribute | Value |
---|---|---|---|---|
0..0 | 1..1 |
| ||
1..* | 1..1 | |||
1..1 | ||||
0..1 | ||||
1..1 |
Definition status:
Applies to:
<< 77343006 |Angiography (procedure)|: [1..*] 260686004 |Method| = << 278110001 |Radiographic imaging|, [0..0] 363703001 |Has intent (attribute)| = 429892002 |Guidance intent (qualifier value)|
Template language:
[[~1..* @AngioRoleGroup]]{
[[~1..1]] 260686004 |Method (attribute)| = [[ +id ( << 278110001 |Radiographic imaging - action (qualifier value)| ) @Imagingaction ]] ,
[[~1..1]] 405813007 |Procedure site - Direct (attribute)| = [[ +id ( << 59820001 |Blood vessel structure (body structure)| ) @Bloodvessel ]] ,
[[~1..1]] 424361007 |Using substance (attribute)| = [[ +id ( << 385420005 |Contrast media (substance)| ) @Substance ]] ,
[[~0..1]] 363700003 |Direct morphology (attribute)| = [[ +id ( < 49755003 |Morphologically abnormal structure (morphologic abnormality)| ) @Morphology ]] }
Link to the misaligned concept report:
https://docs.google.com/spreadsheets/d/17ZXzUvPoUer7StTUVzjwLIE3JNwHO5HCiVGU8tUgRmQ/edit?usp=sharing
Rules for generating descriptions:
- Apply General rules for generating descriptions for templates;
- Apply Enhancements for the Template Language;
- If the direct site of the angiography is specified as an artery rather than a blood vessel, an additional description should be added SYN: [Imaging] arteriography of [body structure] with [substance], should be added as acceptable in both US/GB and case significance should be ci.
- If the direct site of the angiography is specified as an vein rather than a blood vessel, an additional description should be added SYN: [Imaging] venography of [body structure] with [substance], should be added as acceptable in both US/GB and case significance should be ci.
- For computed tomography angiography, the naming should be FSN: Computed tomography angiography of [body structure] with [substance] (procedure), PT: CT angiography of [body structure] with [substance] - This PT should use case significance CS, SYN: Computed tomography angiography of [body structure] with [substance].
- For fluoroscopic angiography, the naming should be FSN: Fluoroscopic angiography of [body structure] with [substance] (procedure), PT: Fluoroscopic angiography of [body structure] with [substance].
JIRA ticket:
- INFRA-8161Getting issue details... STATUS
4 Comments
Mark Banks
Hi Yongsheng Gao, here is the additional angiography template for those that use radiographic imaging. Whilst the modelling now must include a type of contrast, I have left the naming template as "with [substance]" as it could be a subtype.
Please could you review when you have time, thanks.
Yongsheng Gao
Hi Mark Banks, I have made some minor changes. It is great that this template has identified concepts modelled 'angiography' by radiographic imaging without contrast. The updates are needed for the method or using substance. Cheers, Yong
Mark Banks
Great, thanks Yongsheng Gao.
Yes, I'll get round to sorting those misaligned ones very soon.
Thanks again,
Mark
Yongsheng Gao
This template has been archived after the updates in the editorial guide.
https://confluence.ihtsdotools.org/display/SCTEMPLATES/Radiographic+angiography+(procedure)+-+v1.0
https://jira.ihtsdotools.org/browse/TMS-98
‘Radiographic’ is no longer allowed for descriptions and same for method 278110001|Radiographic imaging - action (qualifier value)|
https://confluence.ihtsdotools.org/display/DOCEG/Radiographic+Imaging,+X-ray+and+Plain+X-ray