Time:
0100 - 0430 PST
0900-1230 UTC
Zoom Meeting Details
Topic: SNOMED CT Editorial AG (Open to Observers) (09:00-12:30 BST)
Time: Apr 4, 2023 09:00 London
Join from PC, Mac, Linux, iOS or Android:
https://snomed.zoom.us/j/82859206599?pwd=d1lmVDUyMm9odDlJeFBmeU1td0h4QT09
Password: 128420
Meeting ID: 828 5920 6599
Password: 128420
International numbers available: https://snomed.zoom.us/u/kk2fCQHDg
Or Skype for Business (Lync):
https://snomed.zoom.us/skype/82859206599
Attendees
Chair:
AG Members:
Invitees:
Apologies:
Meeting Files:
Objectives
- Obtain consensus on agenda items
Discussion items
Item | Description | Owner | Notes | Action |
---|---|---|---|---|
1 | Call to order and role call | This meeting is being recorded to ensure that important discussion points are not missed in the minutes. The recording will be available to the SNOMED International community. Joining the meeting by accepting the Zoom prompt declares that you have no objection to your comments being recorded |
| |
2 | Conflicts of interest and agenda review | None noted. | ||
3 | Dose forms Briefing Note | A Briefing Note has been written to inform the community of practice about changes to the dose form modeling to include the use of newly published concentrate dose forms (added as required by the EDQM mapping project) in the modeling of clinical drugs in the International Edition of SNOMED CT. The intent is to gather feedback on a change to Editorial Guidance for clinical drug concepts with dose form of drops or spray (feedback to be received by 22th April). The document is attached to the meeting agenda above. DIscussion: The briefing note was presented and we have requested input on the proposal by April 22, 2023 | ||
4 | Inactivation of Navigational concept hierarchy briefing note | At the 2023-02-27 EAG conference call, the EAG approved the inactivation of the Navigational concept hierarchy. The EAG members requested a Briefing Note for the Community of Practice outlining the rationale and steps for inactivation. The briefing note is attached for review. Update 4/4/2023: In discussions with the UK, it was discovered that the current use of Navigational concepts are the result of maps from Read version 2 to SNOMED provided to primary care vendors. The erroneous nature of the maps may be a result of the movement of concepts from their original location in the taxonomy to the Navigational concept hierarchy at variable times in the past. Examples: Concept Original hierarchy Moved to Navigation hierarchy 160237006 History/symptoms (navigational concept) Context-dependent category 2006-01-31 309157004 Normal laboratory finding (navigational concept) Findings 2009-07-31 267368005 Endocrine, nutritional, metabolic and immunity disorders Disorders 2003-01-31 243800003 Test categorized by action status (navigational concept) Context-dependent category 2010-01-31 250541005 Biochemical finding (navigational concept) Findings 2009-07-31 The UK will provide SNOMED International with a list of mappings to navigational concepts and their current use cases. SNOMED will provide replacement concepts for these prior to inactivation of the navigational concept. Briefing note will be revised to reflect this new information. Discussion: Review of the proposed inactivation based on the new information from the UK. Decision: SI will update the briefing note to reflect the new information and distribute it to the EAG, CMAG and Clinical leads groups. |
| |
5 | At risk concept modeling update | Based on input from Monique van Berkum (document attached to agenda above) and the Gravity project, 13 "at risk" concepts submitted by the Gravity project were inactivated. Additionally, a recommendation to create the necessary pre-coordinated concepts for use in the HAS REALIZATION relationship for the At risk model has mitigated the current need to extend the range of HAS INTERPRETATION, for the purposes of modeling risk findings as well as eliminated the need for a DUE TO relationship that resulted in inconsistent modeling patterns. This remodeling has been performed and should be available in the May 2023 release. The full model currently being used for "At risk" concepts is defined in the template located at: At [qualifier] risk of [finding/event] (finding) - Ready for review High vs. increased and Low vs. decreased Based on the discussion at previous conference call, 1144845004 |Risk of suicide decreased (finding)| has been inactivated and replaced by 394687007 |At low risk for suicide (finding)|. A new concept grouper 1279548003 |Finding of low risk level (finding)| has been created to aggregate low risk concepts. Decreased risk concepts are no longer accepted due to ambiguity as to relative decrease vs. below an established normal level. Many vague risk concepts have been inactivated and replaced with more explicit and specific concepts (e.g. 409046006 |Perinatal risk (finding)| replaced by 1269553009 |At increased risk for perinatal disorder (finding)| Discussion: Jim Case updated the group on the changes to "At risk" findings based on previous discussions with the EAG. Decision: It was determined that for this use case, there is no need to consider changing the range of the HAS INTERPRETATION attribute to support Clinical findings or Procedures. |
| |
6 | Expansion of the range of HAS INTERPRETATION | James R. Campbell | Document by James R. Campbell related to risk calculators is attached to the agenda. The primary premise is that the "proper use of HAS_INTERPRETATION when INTERPRETATION has value of an Observable entity is that the valueset must adhere rigorously to datatype restrictions specified by the SCALE_TYPE defining the Observable concept." Additionally, the following extensions to the concept model are proposed: 1) Expand the valueset constraints for 719722006|Has realization (attribute)| Note: Range for this attribute is currently << 272379006 |Event (event)| OR << 404684003 |Clinical finding (finding)| OR << 71388002 |Procedure (procedure)| OR << 719982003 |Process (qualifier value)|
In reference to content development in the International release, the following must be considered:
Discussion: James R. Campbell described the use of risk calculators at UNMC. One question that had arisen was the editorial decision to not include a value for the SCALE attribute to Observable entities in the international release. This was due to the fact that the "expected" scale was adequately described by the PROPERTY attribute value, and the TECHNIQUE attribute value as well as the observation that many of these risk calculators allowed for either a Ordinal or quantitative value. However, the Regenstrief/SNOMED agreement obviates much of this as the LOINC extension will necessarily contain SCALE TYPE as that is a required LOINC part in the definition of a LOINC term. A discussion ensued on the need to create clinical findings that represented the combined observable-value that is represented by the INTERPRETS/HAS INTERPRETATION relationship group. This did not seem to be the way that the data are collected in the EHR. However, it was recognized that there is a need for clinical findings to be used as members of a value set bound to an observable to support assessments. Decision: The discussion ended with consensus that there is no compelling use case at this time to expand the range of HAS INTERPRETATION at this time. The need to revise the editorial policy related to the inclusion of SCALE TYPE in modeling observable entities in the International release will be re-evaluated by the SNOMED content team. | |
7 | Mechanical Complication of device | Jim Case | Should "Mechanical complication of device" be a disorder or a finding? Current situation: 111746009 |Mechanical complication of device (disorder)| has 215 subtypes, all of which refer to a failure of a device without specifying a deleterious effect on the patient. e.g. 285961000119107 |Mechanical breakdown of prosthetic heart valve (disorder)| We also have disorder concepts that refer to a patient condition due to mechanical failure of a device e.g. 5053004 |Cardiac insufficiency due to prosthesis (disorder)| Without specifying the resultant condition associated with device mechanical issues, is it appropriate that these are represented as patient disorders, or should they be findings that may be related to disorders in the patient? A briefing note using "Leakage of device as an example is located here. Discussion: Without an associated condition in the patient it is unclear whether there is an adverse impact on the patient. In general, if the device is implanted, it can be assumed that there is a negative impact. These should be retained as disorders. Each of the subtypes would need to be evaluated as to the potential impact on the patient. 2023-04-04 Additional issues and questions:
Definition provided by John Snyder - "Medically implanted devices refer to any manufactured device, prosthesis, or biological construct that is surgically implanted into or physically attached to the body to aid in the diagnosis, treatment, or monitoring of a medical condition". Discussion: Implantable devices might be considered as a type of body part, thus a disorder of the device would of necessity cause a problem in the patient and should be a disorder. While there may not be a morphological abnormality, there is an abnormality of the device. Is a new attribute needed to represent device abnormality? This discussion is restricted to medical devices and not transplanted tissues and organs. Some implantable devices are not prostheses. With reference to a proposed definition, what does physically attached mean? Look at how FHIR has addressed this. Should imply some introduction method, rather than just an attachment to the body. The top level concept could be moved to clinical findings. There is an issue with the term "complication". Subtypes would be individually reassessed. Propose that the disorder boundary start with mechanical complication of implanted device. Kin Wah will provide documents related to a discussion on implantable devices. Upon investigation, these concepts (i.e. Mechanical complication) are classification derived (ICD-9, ICD-10, and ICD-11) and refer to injury or harm to a patient caused by a failure, breakdown, or malfunction of a device. Coding guidance indicated that (for ICD-11) the disorder caused by the mechanical complication should be coded first and then associated with the device. Thus, the intended meaning of these concepts imply a disorder in the patient due to some issue with the device. The actual terms are index terms in the ICD. Example: PK91.22 Cardiovascular devices associated with injury or harm, mechanical or bioprosthetic valves (ICD-11) Index term: Mechanical complication of heart valve prosthesis This would suggest that these concepts are correctly placed in the taxonomy, but are | |
8 | Intermediate primitive parent and definition status of subtype | Review of Glossary definition for "Sufficiently defined concept". See sufficiently defined concept Additional information on Necessary and sufficient conditions: D.2 Necessary and Sufficient - Examples Can a concept be sufficiently defined if part of the meaning of the FSN is captured only in the wording of a stated primitive parent, not in defining attribute-value relationships? For example: Joint laxity (finding) is primitive since it has no defining relationship(s) that capture the "laxity" aspect of the FSN meaning. Many of its subtypes (e.g. Elbow joint laxity (finding), Hand joint laxity (finding) etc.) are modeled as sufficiently defined based on the stated parent Joint laxity plus the finding site relationship specifying the joint involved? Inconsistency between the Editorial Guide and the SNOMED Glossary: Current Editorial guide states "A concept is sufficiently defined if its defining characteristics are adequate to define it relative to its immediate supertypes". It is not clear whether "defining characteristics" here refers to defining attribute-value relationships specifically or to the logical definition as a whole.
The SNOMED Glossary states: ""A sufficiently defined concept has at least one sufficient definition that distinguishes it from any concepts or expressions that are neither equivalent to, nor subtypes of, the defined concept".
The Glossary also states "Prior to July 2018, SNOMED CT could only support one sufficient definition for each concept could not represent the 8801005 | Secondary diabetes mellitus (disorder)| example above (Note: this example is no longer valid and needs updating in the glossary). A further limitation, that also prevented formal representation of that example was the stated relationship file was only able to represent necessary conditions.".
Lastly, there is a statement: "Following these changes a concept will only be marked as sufficiently defined if it is sufficiently defined by relationships. However, the OWL axioms may provide a sufficient definition that cannot be fully represented as relationships."
Discussion: Concepts with identical definitions aside from the Definition status may be classified as supertype/subtypes, due to the limitations of the concept model to allow for more robust definitions. This is being left with the EAG for additional comments to be reviewed at the April meeting. There is a question about whether the browser can be modified to show an icon that can identify a concept as having GCIs. A question will be forwarded to the tech team. Update 2023-03-26: The current SNOMED Browser displays concepts with GCIs in the stated diagram view; e.g.: Discussion (2023-04-04): |
| |
9 | Inspection vs. exploration actions | Jim Case | A query was posed as to the difference between 129433002 |Inspection - action (qualifier value)| and 281615006 |Exploration - action (qualifier value)|, both subtypes of 302199004 |Examination - action (qualifier value)|. The internal consensus was that these are clinically different with the former limited to visual evaluation and the latter implying an active examination. Various medical dictionary definitions concur with this view: e.g. Exploration - "An active examination, usually involving endoscopy or a surgical procedure, to ascertain conditions present as an aid in diagnosis. - Inspection - "The visual examination of the body using the eyes and a lighted instrument if needed. The sense of smell may also be used. - Gale Encyclopedia of Medicine. Copyright 2008 The Gale Group, Inc. All rights reserved." This would imply that surgical procedures would more frequently use exploration as the METHOD than inspection; however, this does not appear to be the case <<387713003 |Surgical procedure|:260686004 |Method| = 129433002 |Inspection - action| = 306 <<387713003 |Surgical procedure|:260686004 |Method| = 281615006 |Exploration - action| = 150 For non-surgical procedures the difference is more extreme (<<71388002 |Procedure| MINUS <<387713003 |Surgical procedure|):260686004 |Method| = 129433002 |Inspection - action| = 710 (<<71388002 |Procedure| MINUS <<387713003 |Surgical procedure|):260686004 |Method| = 281615006 |Exploration - action| = 220 Many of the non-surgical procedures modeled using inspection are some form of endoscopy. Given the definitions above and the consensus of the internal content development team, should SI undertake a project replacing Inspection with Exploration for surgical and endoscopic procedures? It is anticipated that much of this can be done automatically. Discussion: Need to review the definition associated with Inspection procedure and Exploration procedure. General consensus is that we do not change the modeling unless there is a clear distinction that can be applied other than what is expressed in the FSN. | |
10 | AOB | EAG | ||
11 | Next meeting | EAG | Next meeting April 4. SNOMED business meeting | |