Resource element (CodeableConcept) | FHIR ValueSet | SNOMED CT attribute | SNOMED CT range | Comments |
---|---|---|---|---|
Specimen.type Suggest rename to .substance | https://www.hl7.org/fhir/v2/0487/index.html A v2 value set reused for FHIR | << < 105590001 |Substance (substance)| (in which case method and site should also be populated) OR < 49755003 |Morphologically abnormal structure (morphologic abnormality)| OR < 260787004 |Physical object (physical object)| | A ConceptMap exists: https://www.hl7.org/fhir/conceptmap-example-specimen-type.html Another set of specimen type codes used for biobanking, SPREC, is available here (tables 1 and 2). | |
Suggest new element: Specimen.code | << < 123038009 | Specimen (specimen) | | Pre or post coordinated concept which would preclude the population of other code fields. | ||
Specimen.collection.method | https://www.hl7.org/fhir/valueset-specimen-collection-method.html Extensional ValueSet | 118171006 | Specimen procedure (attribute) | | << < 71388002 | Procedure (procedure) | | |
Specimen.collection.bodySite Suggest rename to .source YGA suggests adding this rather than renaming so as to avoid overloading an element with heterogenous data. | Include codes from | 118169006 | Specimen source topography (attribute) | | << < 49755003 Morphologically abnormal structure | Previously << 442083009 | Anatomical or acquired body structure | |
Specimen.collection.method | Note that the method would encompass the device used in obtaining the specimen <706041008 |Device for body fluid and tissue collection/transfer/processing (physical object)| | |||
Specimen.processing.procedure | https://www.hl7.org/fhir/valueset-specimen-processing-procedure.html A v2 value set reused for FHIR (Most probably nothing in SNOMED CT corresponding directly to those codes) | 118171006 | Specimen procedure (attribute) | | << 71388002 | Procedure (procedure) | | |
Specimen.processing.additive-->Substance.code | Include codes from Include codes from | primitive | << 105590001 | Substance (substance) | | |
Specimen.container.type | Include codes from | - | ?? << 434711009 | Specimen container (physical object) | ?? Consider << 706437002 |Container (physical object)| still doesn't contain test tube however! | ValueSet not adequate, e.g. 337386000 | Test tube (physical object) | not included. Generally, little content in SNOMED CT. Terminology requirements?? SPREC, linked above also has a set of container types. |
Specimen.container.additiveCodeableConcept | https://www.hl7.org/fhir/v2/0371/index.html A v2 value set reused for FHIR | primitive | << 105590001 | Substance (substance) | | |
Specimen.subject ?? Catered for by Specimen.source | 118170007 | Specimen source identity (attribute) | | << 125676002 | Person | OR << 35359004 | Family | OR << 133928008 | Community | OR << 49062001 | Device | OR << 276339004 | Environment | | Overlapping semantics between FHIR and SNOMED CT FHIR is not interested in specifying the class of subject, it would just link to the instance of the particular person resource. | |
Specimen.type ?? Catered for by Specimen.source | 118168003 | Specimen source morphology (attribute) | | << 49755003 | Morphologically abnormal structure | | SNOMED CT distinguishes site, abnormal morphology, and substance when specifying the material contents of the specimen, while FHIR only has type and collection.bodySite | |
Specimen.type ?? Catered for by Specimen.substance (previously type) | 370133003 | Specimen substance (attribute) | | << 105590001 | Substance (substance) | |
...