...
Items | Hierarchy/Topic | EARLY VISIBILITY OF PROPOSED CONTENT CHANGES | Planned Release timing (*this is provisional only and is subject to change) |
---|---|---|---|
1. | Procedure | Update Hierarchy 363680008|Radiographic imaging Procedure (procedure)|and Descendants A Briefing Note documenting the proposed changes for the hierarchy 363680008|Radiographic imaging procedure (procedure)| and descendants was shared with the Editorial Advisory Group, Clinical Leads Group, Member Forum, Content Managers Advisory Group, and other key stakeholders in July 2023. Feedback was received from a wide range of stakeholders. In response to this feedback, the proposed changes to the hierarchy have been modified. These modifications will address issues raised in the feedback. This Informational Briefing Note summarizes the changes that will be implemented. Implementation of the content changes will commence in Q4 2023. The updates will be implemented in sub-hierarchies and promoted over a number of international monthly releases until complete. | Ongoing in phases across 2024 International Releases *See item 15 below - Remodel 241686001|Dual energy X-ray absorptiometry (procedure)| and Subtypes |
2. | Content Improvement | Updates to the Inactivation Reason and Historical Association for 'On Examination' and 'Complaining of' Inactive Content Many of the 'on examination' and 'complaining of' concepts were previously inactivated with the inactivation reason of |Moved elsewhere| with a historical association value |Extension Namespace 1000000|. This content will be updated with an inactivation reason of |Non-conformance to editorial policy| and a historical association of |Alternative| to a suitable international concept. | Q4 2024 International Release |
3. | Clinical Finding/Procedure | Patient/Subject concepts in the Clinical finding and Procedure Hierarchies Concepts in the Clinical finding and Procedure hierarchies that contain the explicit context of patient or subject will be inactivated and replaced with concepts without this explicit context. For further information please see briefing note. | On hold - to be determined |
4. | Clinical Finding | Substance Abuse/Use There has been a shift from the term "substance abuse" to a more nuanced understanding of substance use disorders in this domain which is reflected in both ICD-11 and DSM-5 indicating a greater emphasis on the spectrum of substance-related problems. Several members have expressed the need for content updates to incorporate this change and to simplify the translation process. Consequently, efforts to revise the content associated with 66214007 |Substance abuse (disorder)| will begin and is expected to be completed by the end of Q2. An example of the content structure and terming using opioid use is shown. Specifically, descriptions will be added with “harmful pattern of X substance use” replacing the term “abuse” in the FSN and PT however the “abuse” descriptions are persisted as synonyms to facilitate searching. In most cases there is no change in meaning, therefore the concepts will not be inactivated. Approximately 100 existing concepts relating to “abuse” will be affected together with the addition of new concepts to represent “harmful episode” and the higher level “X substance use disorder | October 2024 International Release |
5. | Clinical Finding | Inactivation of Complication Disorder Concepts (371 concepts) The inactivation of concepts that reference “complication” without specifying the nature of the complication is planned. The primitive “Complication (disorder)” grouper was inactivated in 2022 due to a lack of consistency or definition of what would properly be assigned as a subtype. The concepts will be inactivated with inactivation reason “Classification derived concept” and replacement by the parent concept. For further information please see this briefing note. | Beginning June 2024 International Release and then subsequent releases until complete |
6. | Procedure | Angioplasty procedures In response to several enquiries from members about the apparent duplication of concepts and descriptions for procedures representing 'Percutaneous transluminal angioplasty' an analysis of the content in this area is underway. It is expected to result in inactivation of duplicates, updates to the descriptions of published concepts and remodeling to represent the imaging guidance aspect where appropriate. After the analysis of the impact has been completed, a Briefing Note will be dispatched to provide details of the changes. Examples of potential duplication:
| Q4 2024 International Release |
7. | Procedure | Review 1263452006 |Anesthesia and/or sedation procedure (procedure)| A review of the 1263452006 |Anesthesia and/or sedation procedure (procedure)| hierarchy is in progress, the focus is on:
| Q4 2024 International Release |
8. | Procedure | Review 48537004 |Bypass graft (procedure)| A review of the 48537004 |Bypass graft (procedure)| hierarchy is in progress, the focus is on:
| Q4 2024 International Release |
9. | Procedure | Review Use of 424876005 |Surgical approach (attribute)| A review to generalize 424876005 |Surgical approach (attribute)| to allow non-surgical procedures to be modeled with a subtype of <<103379005 |Procedural approach (qualifier value)| is in progress.
| Q4 2024 International Release |
10. | Procedure | Review 1287742003 |Radiotherapy (procedure)| A review of 1287742003 |Radiotherapy (procedure)| hierarchy is in progress, the focus is on:
| Q4 2024 International Release |
11. | Procedure | Review 424226004 |Using device (attribute)| vs. 363699004 |Direct device (attribute)| for Modeling of Repair Procedures 424226004 |Using device (attribute)| and 363699004 |Direct device (attribute)| are used interchangeably for modeling of repair procedures within the Repair group of relationships.
| Q4 2024 International Release |
12. | Substance | Update << 385420005 |Contrast media (substance)| The 95 subtypes of 385420005 |Contrast media (substance) will be updated. Concepts will be remodeled based on discussion with stakeholders. New substance concepts including groupers will be required. | Q4 2024 International Release |
13. | Procedure | Proposed New Model for Solid Organ and Tissue Transplant Procedures Feedback is requested for a proposed new model for solid organ and tissue transplant procedures. Please see briefing note here. Deadline to submit feedback is 15 June 2024. | 2024 International Release |
14. | Clinical Finding/Observable Entity | Inactivation of 302081005|Finding of sex of baby (finding)| and Subtypes 302081005|Finding of sex of baby (finding)| and subtypes will be inactivated, 'baby' may mean fetus, neonate, infant. | October 2024 International Release |
15. | Procedure | Remodel 241686001|Dual energy X-ray absorptiometry (procedure)| and Subtypes As part of the ongoing work to update hierarchy 363680008|Radiographic imaging Procedure (procedure)| and descendants (see item 1 above), 241686001|Dual energy X-ray absorptiometry (procedure)| and descendants will be remodeled along with associated finding and situation concepts. A new imaging action will be added - Dual energy X-ray absorptiometry imaging - action (qualifier value)| The following concepts will be inactivated:
The editorial guide will be updated. | October 2024 International Release |
16. | Descriptions Update | Forward slash in FSN A review has commenced of those concepts with a forward slash in their FSN. Editorial guidance exists disallowing the use of forward slashes in FSNs, and we have commenced a systematic review of those existing terms containing them. Many areas are excluded for example, medicinal products where strength /1 is the denominator, assessment scales, explicit "and/or", gene names, enzyme and other substance naming, organisms, ratios, per in units (or future consideration), intervertebral structures, content added with an Orphanet map and others. The review is ongoing. If the meaning is clear i.e. single meaning there is no change but groupers, disjoint ('or)' terming and ambiguous terms will be reviewed and possibly inactivated or have a new replacement FSN without a forward slash. Subject matter experts are being consulted as part of this work. | Q4 2024 International Release Q1 2025 International Release |
17. | Descriptions Update | Inactivation of Descriptions with Asterisk Eight concepts containing an asterisk instead of a superscript to represent "power of," e.g. 277288007 |10*9/liter (qualifier value)|, will be inactivated with reason ambiguous. New replacement concepts will be created, e.g. 1348323004 |10^9/liter (qualifier value)|. The concepts scheduled for inactivation and replacement are all subtypes of 282409001 |Nominated concentrations (qualifier value)|). Editorial guidance is available here. | October 2024 International Release. |
2024 Published Content Changes With Confirmed Release Date
...