...
Items | Hierarchy/Topic | EARLY VISIBILITY OF PROPOSED CONTENT CHANGES | Planned Release timing (*this is provisional only and is subject to change) |
---|---|---|---|
1. | Body Structure | Inactivation of 9258009|Gravid uterus structure (body structure)| This concept will be inactivated, content that is modeled with this concept will be remodeled with a site of 35039007|Uterine structure (body structure)| along with occurrence <<307159006|Pregnancy time period (qualifier value)|. The domain of 246454002 |Occurrence (attribute)| has been extended in the October 2023 release to include << 71388002 |Procedure (procedure)| to support these content changes. Content areas that will be updated include 386811000|Fetal procedure (procedure)| and 386637004|Obstetric procedure (procedure)|. | Q2 2024 International Release |
2. | Body Structure | Inactivation of Concepts Specified Male/Female in Descriptions Subtypes of 67770001 |Male mammary gland structure (body structure)| and 91532001 |Female mammary gland structure (body structure)| and their associated disorder and specimen concepts. Further information is available here (Confluence log in required). NOTE: this update will include the inactivation of neoplasm concepts that specify male/female, this includes <<126927001|Neoplasm of female breast (disorder)| <<126937006|Neoplasm of male breast (disorder)| These concepts will be replaced with a concept that does not specify male/female, a new concept will be added where one does not already exist. | April/May 2024 International Release |
3. | Clinical Finding | Update for Concepts Using 'Caused by' Clinical finding concepts containing "Caused by" in their FSN will be reviewed and will be updated (if applicable) according to the editorial guidelines related to causation here. There is one area where work is still in progress:
| 2024 International Release |
4. | Procedure | Update Hierarchy 363680008|Radiographic imaging Procedure (procedure)|and Descendants A Briefing Note documenting the proposed changes for the hierarchy 363680008|Radiographic imaging procedure (procedure)| and descendants was shared with the Editorial Advisory Group, Clinical Leads Group, Member Forum, Content Managers Advisory Group, and other key stakeholders in July 2023. Feedback was received from a wide range of stakeholders. In response to this feedback, the proposed changes to the hierarchy have been modified. These modifications will address issues raised in the feedback. This Informational Briefing Note summarizes the changes that will be implemented. Implementation of the content changes will commence in Q4 2023. The updates will be implemented in sub-hierarchies and promoted over a number of international monthly releases until complete. | April 2024 release:
Remaining changes across 2024 International Releases |
5. | Content Improvement | Updates to the Inactivation Reason and Historical Association for 'On Examination' and 'Complaining of' Inactive Content Many of the 'on examination' and 'complaining of' concepts were previously inactivated with the inactivation reason of |Moved elsewhere| with a historical association value |Extension Namespace 1000000|. This content will be updated with an inactivation reason of |Non-conformance to editorial policy| and a historical association of |Alternative| to a suitable international concept. | Q2 2024 International Release |
6. | Social Context | Ethnic/Racial Group Social Context Content Inactivation The subtypes of 372148003 |Ethnic group (ethnic group)| and 415229000 |Racial group (racial group)| will be inactivated as they are out of scope for the International Edition. A briefing note is available here. | In discussion - to be determined |
7. | Clinical Finding/Procedure | Patient/Subject concepts in the Clinical finding and Procedure Hierarchies Concepts in the Clinical finding and Procedure hierarchies that contain the explicit context of patient or subject will be inactivated and replaced with concepts without this explicit context. For further information please see briefing note. | On hold - to be determined |
8. | Procedure | Inactivation of 277132007|Therapeutic procedure (procedure) The concept 277132007 |Therapeutic procedure (procedure) will be inactivated with the inactivation reason of Outdated and a replacement association target of 71388002 |Procedure (procedure)|. The nearly 2000 descendants will be reviewed as to the appropriateness of either the Has intent (attribute) of Therapeutic intent, or a Method (attribute) of Therapy - action. For further information please see briefing note. | Q1-Q2 2024 International Release |
9. | Annotation | OWL Axiom Expressions for Annotation Properties The new annotation properties are represented in the OWL expression axiom refset as follows:
These axiom updates are published in the March 2024 International Edition release. The authoring tool has been updated to ensure all new subconcepts of 1295447006 |Annotation attribute (attribute)| are represented as SubAnnotationPropertyOf(). Other tools will be updated to correctly consume the updated syntax. This will be carefully tested and rolled out over the next few months. | Q2 2024 International Release |
10. | Qualifier Value | Addition of New Technique Qualifier Value Concepts Around 80 new laboratory technique concepts will be added in the 272394005 |Technique (qualifier value)| subhierarchy. | Q1-Q2 2024 International Release |
11. | Qualifier Value | Change Parent for 410460000|Illumination - action (qualifier value)| and Subtypes 410460000|Illumination - action (qualifier value)| and descendants will be updated to be a subtype of 272394005|Technique (qualifier value)|. The concepts will not be inactivated. Descriptions that currently include '- action’ will be inactivated and replaced. Concepts that are currently modeled with method 410460000|Illumination - action (qualifier value)| will be remodeled with a method of 360037004|Imaging - action (qualifier value)|. These changes will complete this Content Tracker. | April 2024 International Release |
12. | Procedure | Inactivation of 118661008|Physician service (procedure)| and Descendants 118661008|Physician service (procedure)| and subtypes will be inactivated and replaced with concepts that are a subtype of 224891009|Healthcare services (qualifier value)| where appropriate. These changes will complete this Content Tracker. | April 2024 International Release |
13. | Clinical Finding | Inactivation of Mechanical Complication of <x> Device In October 2023 the Editorial Advisory Group made a decision that the concepts that represent a mechanical complication of <x> device are ambiguous. Following this a a briefing note was shared with the community of practice to both inform and collect feedback. This feedback has been reviewed and the work will be proceeding. The concepts will be inactivated as ambiguous with a historical association to 473023007 |Complication associated with device (disorder)| or a suitable subtype. | Q2 2024 International Release |
...